Compare tool

Compare models side by side

Pick two to four models. The best figure in each row is marked, and every number comes from the maker, NEEP or ENERGY STAR. Copy the URL to share a comparison.

All mini-splits & heat pumps ranked →All dehumidifiers ranked →All window, wall & room units ranked →All heating ranked →All parts, tools & supplies ranked →

SpecCooper & Hunter Olivia Hyper Heat 24,000 BTU 230VSenville Elite 24,000 BTU 230V
PhotoCooper & Hunter Olivia Hyper Heat 24,000 BTU 230VSenville Elite 24,000 BTU 230V
Our scoreSCORE6.6 / 10SCORE7.6 / 10
Our take24,000 Btu/h at 5°F and a 164 ft max run; NEEP rates its cooling at 23,000 Btu/h.Makes less at 5°F than the 18K (20,000 vs 22,600) and NEEP files it as centrally ducted; the least-documented Elite size.
Nominal size24,000 BTU24,000 BTU
Voltage230V230V
Rated heat at 47°F26,000 BTU/h24,000 BTU/h
Heat at 17°F23,000 BTU/hbest17,100 BTU/h
Heat at 5°F24,000 BTU/hbest20,000 BTU/h
Lowest heating temp-22°F-22°F
Max heat at lowest temp10,900 BTU/hbest10,200 BTU/h
SEER222.325best
HSPF2 (Region IV)13.3best11
Install typeFlareFlare
Line set in box16 ft16 ft
Max line run164 ftn/a
Warranty covers owner installNoNo
Warranty, parts5 yr10 yrbest
Warranty, compressor7 yr10 yrbest
ENERGY STAR Cold ClimateYesYes
ENERGY STARYesYes
RefrigerantR-454BR-454B
Watch out forHyper = CH-RHP outdoor unit; the same Olivia head on a CH-RES/REL outdoor unit is the Regular, rated only to -13°F. Warranty requires a licensed HVAC technician and registration within 60 days with the installer license; the no-registration Out-of-Box warranty excludes online distributors. Sold on Amazon by a third-party seller.Senville's FAQ says no to owner installs; warranty registration asks for the installing company and invoice. Senville's site lists higher HSPF2 than the AHRI figures on NEEP; we use the certified numbers. No published max line length for the 24K; Senville's page lists 24.0 SEER2 / 11.0 EER2 vs 25.0 / 14.0 on NEEP.
More