SCORE7.0 / 10

46,000 Btu/h at 5°F, but a 15,500 Btu/h minimum and 16.5 SEER2; NEEP lists it Cold Climate but not ENERGY STAR.

Specs

SpecMrCool Central Ducted Hyper Heat 2nd Gen 4 ton (CENTRAL-48-HP-C-230B00-O)
Nominal size48,000 BTU
Voltage230V
Rated heat at 47°F50,000 BTU/h
Heat at 17°F39,500 BTU/h
Heat at 5°F46,000 BTU/h
Lowest heating temp-22°F
Max heat at lowest temp25,900 BTU/h
SEER216.5
HSPF2 (Region IV)9.5
Install typeQuick-connect
Max line run246 ft
Warranty covers owner installConditional
Warranty, parts10 yr
Warranty, compressor10 yr
ENERGY STAR Cold ClimateYes
ENERGY STARNo
RefrigerantR-454B
Minimum heat output at 47°F15,500 Btu/h
Condenser electrical208/230V; 38 A MCA, 40 A max breaker
Air handler21.02 in wide; up to 0.8 in. w.c. external static; not for free-blow
Line connectionsOptional No-Vac Quick Connect pre-charged line set, or flare/braze with vacuum; 24.6 ft pre-charge, 0.7 oz/ft beyond
Warranty10 yr parts, compressor and labor (first 90 days on the installing company); professional installer not required with the Quick Connect line set

Sources: NEEP ccASHP list · MRCOOL submittal (mc-CDHH-2) · MRCOOL install manual (May 21 2026) · MRCOOL Central Ducted Hyper Heat warranty (rev. 10.03.24)

Before you buy

  • Install type 'quick-connect' assumes MRCOOL's optional No-Vac line set; the system also ships for flare or braze connections with a vacuum.
  • Some Amazon listings carry older CENTRAL-xx-HP-230A00 model codes; match the 230B00-O suffix.
  • The install manual still calls for a licensed installer and licensed field piping; the warranty is what exempts a Quick Connect install.