Compare tool

Compare models side by side

Pick two to four models. The best figure in each row is marked, and every number comes from the maker, NEEP or ENERGY STAR. Copy the URL to share a comparison.

All mini-splits & heat pumps ranked →All dehumidifiers ranked →All window, wall & room units ranked →All heating ranked →All parts, tools & supplies ranked →

SpecACiQ Essentials 36,000 BTU 230V (R32)MrCool Central Ducted Hyper Heat 2nd Gen 3 ton (CENTRAL-36-HP-C-230B00-O)
PhotoACiQ Essentials 36,000 BTU 230V (R32)MrCool Central Ducted Hyper Heat 2nd Gen 3 ton (CENTRAL-36-HP-C-230B00-O)
Our scoreSCORE6.4 / 10SCORE7.0 / 10
Our takeThe biggest Essentials holds the least of its rating at 5°F, 64% per ACiQ. A single 3-ton head is a lot for one room; check the load first.The standout size: more heat at 5°F (39,000 Btu/h) than at 47°F and 27,800 still available at -22°F. Owner installs allowed with the Quick Connect line set.
Nominal size36,000 BTU36,000 BTU
Voltage230V230V
Rated heat at 47°F36,000 BTU/h37,000 BTU/h
Heat at 17°F28,400 BTU/h31,800 BTU/hbest
Heat at 5°Fn/a39,000 BTU/h
Lowest heating temp-4°F-22°Fbest
Max heat at lowest temp16,800 BTU/h27,800 BTU/hbest
SEER220best17.4
HSPF2 (Region IV)9.510.3best
Install typeFlareQuick-connect
Line set in box16 ftn/a
Max line run98 ft246 ftbest
Warranty covers owner installNoConditional
Warranty, parts4 yr10 yrbest
Warranty, compressor6 yr10 yrbest
ENERGY STAR Cold ClimateNoYes
ENERGY STARNoYes
RefrigerantR-32R-454B
Watch out forTwo Essentials 20 SEER2 lines exist: this R32 one (model numbers with -32-) and an R-454B one with different numbers; NEEP lists only the R-454B units. The 5°F and -4°F figures are ACiQ's own maximums from its submittal, not NEEP or AHRI ratings. Warranty is 3 yr parts / 5 yr compressor unregistered; 4 / 6 needs registration within 90 days, and the whole system must be installed and diagnosed by an EPA-certified technician. Sold on Amazon by HVACDirect Online.Install type 'quick-connect' assumes MRCOOL's optional No-Vac line set; the system also ships for flare or braze connections with a vacuum. Some Amazon listings carry older CENTRAL-xx-HP-230A00 model codes; match the 230B00-O suffix. The install manual still calls for a licensed installer and licensed field piping; the warranty is what exempts a Quick Connect install.
More