Compare mini-splits & heat pumps / Klimaire DIY 5th Gen

Klimaire DIY 5th Gen 36,000 BTU 230V
Klimaire · DIY 5th Gen

Klimaire DIY 5th Gen 36,000 BTU 230V

SCORE6.7 / 10

The odd one out: 19 SEER2, 57% of its rating at 5°F and heating ends at -4°F. Skip it for a cold-climate job.

Specs

SpecKlimaire DIY 5th Gen 36,000 BTU 230V
Nominal size36,000 BTU
Voltage230V
Rated heat at 47°F36,000 BTU/h
Heat at 17°F23,400 BTU/h
Heat at 5°F20,400 BTU/h
Lowest heating temp-4°F
Max heat at lowest temp16,700 BTU/h
SEER219
HSPF2 (Region IV)9
Install typeQuick-connect
Line set in box16 ft
Warranty covers owner installConditional
Warranty, parts5 yr
Warranty, compressor7 yr
ENERGY STARNo
RefrigerantR-454B

Sources: NEEP ccASHP list · Klimaire technical spec sheet · Klimaire DIY manual (2026) · Klimaire warranty page · Klimaire DIY warranty PDF (W0MSQ23-3)

Before you buy

  • Amazon 36K titles say "23 SEER2", but the bullets say up to 19 and NEEP lists 19.0. Believe the 19.
  • The Klimaire Entrada (KIWE/KOIE, -31X, R-32, 17 SEER2) is a flare-and-vacuum unit; the DIY title reads "23 SEER2 Quick Connect".
  • The 4th Gen DIY used the same KIWQ/KOIQ prefixes at 19.0 SEER2; confirm the -45T suffix and R-454B.
  • The warranty page allows DIY installs, but the warranty PDF says licensed contractors only and excludes line sets. Get the DIY terms in writing and register within 45 days.
  • The manual says the EZ-Fast Connect fittings are one-time tightening.

Compare it with