Compare mini-splits & heat pumps / Senville Aura Multi-Zone (R-454B)

Senville Aura 28K Multi-Zone Condenser (SENA-28HF-MOA)
Senville · Aura Multi-Zone (R-454B)

Senville Aura 28K Multi-Zone Condenser (SENA-28HF-MOA)

Model SENA-28HF-MOA · SENA-30HF/T · SENA-30HF/D · SENA-30HF/Q

SCORE6.8 / 10

Holds its full 27,000 Btu/h rating at 5°F, about 50% more than MrCool's DIY 27K, but needs a licensed installer and turns down only to 8,400 Btu/h.

Specs

SpecSenville Aura 28K Multi-Zone Condenser (SENA-28HF-MOA)
Nominal size28,000 BTU
Voltage230V
Rated heat at 47°F27,000 BTU/h
Heat at 17°F30,000 BTU/h
Heat at 5°F27,000 BTU/h
Lowest heating temp-22°F
Max heat at lowest temp14,000 BTU/h
SEER223
HSPF2 (Region IV)10.5
Install typeFlare
Warranty covers owner installNo
Warranty, parts5 yr
Warranty, compressor10 yr
ENERGY STAR Cold ClimateYes
ENERGY STARYes
RefrigerantR-454B
Zones2-4 indoor units
Minimum heat output at 47°F8,400 Btu/h (whole system)
Refrigerant pre-chargeCombined line length up to 100 ft
Electrical208/230V; 30 A MCA, 35 A max fuse

Sources: NEEP ccASHP list · Senville product pages and spec tables · Senville mini-split warranty certificate · Senville-linked R454B multi-zone service manual

Before you buy

  • MOA outdoor units are listed as R-454B on Senville's pages and NEEP; NEEP lists the MOB units as R-410A, and an owner of an earlier SENA-28HF-MOA reports R-410A. Confirm the refrigerant on the label.
  • Senville's FAQ says owner installs are not supported; the warranty certificate requires a licensed professional, and labor is never covered.

Compare it with

Where we cover it