Compare tool

Compare models side by side

Pick two to four models. The best figure in each row is marked, and every number comes from the maker, NEEP or ENERGY STAR. Copy the URL to share a comparison.

All mini-splits & heat pumps ranked →All dehumidifiers ranked →All window, wall & room units ranked →All heating ranked →All parts, tools & supplies ranked →

SpecSenville Aura 28K Multi-Zone Condenser (SENA-28HF-MOA)MrCool Universal 2.5-ton R-454B (UHP18030-O + UAH18030-O)
PhotoSenville Aura 28K Multi-Zone Condenser (SENA-28HF-MOA)MrCool Universal 2.5-ton R-454B (UHP18030-O + UAH18030-O)
Our scoreSCORE6.8 / 10SCORE6.7 / 10
Our takeHolds its full 27,000 Btu/h rating at 5°F, about 50% more than MrCool's DIY 27K, but needs a licensed installer and turns down only to 8,400 Btu/h.33,200 Btu/h at 5°F, slightly above its 47°F rating, with 10.8 HSPF2, the best in the line. Warranty requires a professional installer and an authorized dealer. We don't have a verified Amazon listing for this size.
Nominal size28,000 BTU30,000 BTU
Voltage230V230V
Rated heat at 47°F27,000 BTU/h33,000 BTU/h
Heat at 17°F30,000 BTU/hbest24,000 BTU/h
Heat at 5°F27,000 BTU/h33,200 BTU/hbest
Lowest heating temp-22°F-22°F
Max heat at lowest temp14,000 BTU/h17,900 BTU/hbest
SEER223best17.2
HSPF2 (Region IV)10.510.8best
Install typeFlareFlare
Max line runn/a164 ft
Warranty covers owner installNoNo
Warranty, parts5 yr10 yrbest
Warranty, compressor10 yr10 yr
ENERGY STAR Cold ClimateYesYes
ENERGY STARYesYes
RefrigerantR-454BR-454B
Watch out forMOA outdoor units are listed as R-454B on Senville's pages and NEEP; NEEP lists the MOB units as R-410A, and an owner of an earlier SENA-28HF-MOA reports R-410A. Confirm the refrigerant on the label. Senville's FAQ says owner installs are not supported; the warranty certificate requires a licensed professional, and labor is never covered.This is the 2nd-gen R-454B Universal (model numbers ending -O); most owner history online is about the discontinued R-410A first generation. MRCOOL's printed warranty requires a professional installer and an authorized dealer; the Central Ducted Hyper Heat 2nd Gen warranty allows owner installs with the Quick Connect line set. NEEP ratings with MRCOOL cased coils on a furnace are lower than with the matched UAH air handler, and some coil pairings aren't ENERGY STAR Cold Climate.
More